Language Seletion

Page QR Code

Ramdon Products

[PLT3050B] USB3.0 Production Line Tester
[PLT3050B] USB3.0 Production Line Tester
[HDMI-CR02AM] HDMI1.4 Active Type C Receptacle Fixture
[HDMI-CR02AM] HDMI1.4 Active Type C Receptacle Fixture
[LT-SATA1.0] SATA Standard Fixture Set
[LT-SATA1.0] SATA Standard Fixture Set
[DP-01ARM] DisplayPort Receptacle Fixture
[DP-01ARM] DisplayPort Receptacle Fixture
[PLT2050D] HDMI Production Tester
[PLT2050D] HDMI Production Tester
[HDMI-CP01A] HDMI1.4 Type C Plug with Power Fixture
[HDMI-CP01A] HDMI1.4 Type C Plug with Power Fixture
E5071C ENA Network Analyzer
E5071C ENA Network Analyzer
[HDMI-AP01AM] HDMI1.4 Type A Plug Fixture for Tektronix
[HDMI-AP01AM] HDMI1.4 Type A Plug Fixture for Tektronix
[MDP-02APM] Mini DP Plug 15G Fixture
[MDP-02APM] Mini DP Plug 15G Fixture
[MHL-CK01AM] MHL Calibration Kit Fixture
[MHL-CK01AM] MHL Calibration Kit Fixture

LiTek Calendar

Last MonthMay 2024Next Month
Su Mo Tu We Th Fr Sa
1 2 3 4
5 6 7 8 9 10 11
12 13 14 15 16 17 18
19 20 21 22 23 24 25
26 27 28 29 30 31
Today

Visit Number

Today : 112112112
Total : 2151598215159821515982151598215159821515982151598
Count5175
WebAdmin - Raw Cable | 2011-11-24 17:10:00

Introduction

 Most of the interfaces are designed by differential 100 ohms system, just like SATA, SAS, Lan, Infiniband, DVI, HDMI, SFP.. etc. The bandwidth of these interfaces is wide up to 20GHz or more. In this way, a good test fixture (Jig) for testing the raw cable with multi-AWG range becomes very important.

 LiTek engineering team devoted 2 years and studied the features of raw cable. Now, LT-100R-20G is suitable for this application.

The LT-100R-20G can be used with many instruments as well as TDR, NA and Pulse Generator ..etc. A engineer can easily inspect the cable performance instead of after assembly.

Read More...

Count4051
WebAdmin - Raw Cable | 2011-11-24 16:34:02

Introduction

 Most of the interfaces are designed by differential 100 ohms system, just like SATA, SAS, Lan, Infiniband, DVI, HDMI, SFP.. etc. The bandwidth of these interfaces is wide up to 10GHz or more. In this way, a good test fixture (Jig) for testing the raw cable with multi-AWG range becomes very important.

 LiTek engineering team devoted 2 years and studied the features of raw cable. Now, LT-100R-4A is suitable for this application.

 The LT-100R-4A can be used with many instruments as well as TDR, NA and Pulse Generator ..etc. A engineer can easily inspect the cable performance instead of after assembly.

Read More...

Count11694
WebAdmin - Raw Cable | 2011-11-24 16:30:01

Introduction

 Most of the interfaces are designed by differential 100 ohms system, just like SATA, SAS, Lan, Infiniband, DVI, HDMI, SFP.. etc. The bandwidth of these interfaces is wide up to 20GHz or more. In this way, a good test fixture (Jig) for testing the raw cable with multi-AWG range becomes very important.

Read More...

Count4089
WebAdmin - DisplayPort | 2011-11-24 16:23:01

Introduction

 LiTek's DPA-12B is a good probe test fixture for Display-Port Source and Sink signal quality and protocol testing. Not only 4 Lane pairs, Aux Channel, but also all low frequencies signal pins had been extended to the SMA connectors and the 2.54-mm pitch connector.

 Since the pin assignments are reversed in Source and Sink sides. DPA-12B probe test fixture is labeled with SLXX for Source end and with LLXX for Sink (Link) end.

Read More...

Count4476
WebAdmin - DisplayPort | 2011-11-24 16:21:36

Introduction

 LiTek's DPA-12 is a good probe test fixture for Display-Port Source and Sink signal quality and protocol testing. Not only 4 Lane pairs, Aux Channel, but also all low frequencies signal pins had been extended to the SMA connectors and the 2.54-mm pitch connector.

 Since the pin assignments are reversed in Source and Sink sides. DPA-12 probe test fixture is labeled with SLXX for Source end and with LLXX for Sink (Link) end.

Read More...

Count3728
WebAdmin - DisplayPort | 2011-11-24 16:14:21

Introduction

 LiTek's DPR-12B is a good receptacle-end test fixture for Display-Port Source and Sink signal quality and protocol testing. Not only 4 Lane pairs, Aux Channel, but also all low frequencies signal pins had been extended to the SMA connectors and the 2.54-mm pitch connector.

 Since the pin assignments are reversed in Source and Sink sides. DPR-12B probe test fixture is labeled with SLXX for Source end and with LLXX for Sink (Link) end.

Read More...

Copyright © by LiTek All Rights Reserved.
LiTek Technologies Tel:+886-3-4951851 Add:4F-3, No.18, Huannan Rd., Pingzhen City, Taoyuan County, Taiwan 32448
LiTek Precision Tel:+86-755-27331770 Add:901R, Shencai Building, Fuyong Boulevard, Fuyong Town, Bao'an District, Shenzhen, Guangdong, China 51810