| |||
Hit Rate 2287
[PRB-50-P10-3AM] Delta L pitch 0.5mm
Impedance and Loss measurements on High speed
PCB become the basic requirement. The PCIE Gen5 data rate, based on 32Gbps, is 4 times than the PCIE Gen3. In hence, the key frequency, 16GHz, will be sensitive and important for the PCB maker to watch. A new 0.5mm pitch probe is built for the measurement higher than 20GHz. The bandwidth of the new probe is up to 40GHz. Litek’s PRB-50-P10-3AM is designed to meet the PCB pad footprint and used to measure the PCB up to 40GHz. To get the pure loss of the PCB traces based on the assigned length, especially in the inner layer is very difficult. Remove the via hole stub and probe effects is an issue that Intel’s Delta-L is a good methodology used to remove the effect of stub and probe effect. Sometimes, PCB makers may make back drills to reduce the via stub effect. Downloads PRB-50-P10-3AM Delta L pitch 0.5mm datasheet -V1.0-Eng |