Home

News-USB

WebAdmin - USB | 2011-11-23 | Count4397
Introduction

 LiTek's USB3.0 Type B receptacle Test fixture (USB3-BR01A) can be used to measure the Device with USB3.0 Protocol Signal Generator or Real-Time Scope after connect USB3.0 Type A to Type B cable assembly. It can also be used to measure USB3.0 Type B plug connectors with suitable test settings.

 For Host Device testing, we can use a determined USB3.0 cable assembly, then connecting to USB3-BR01A. SSRX in the test fixture can be connected to real-time scope. SSTX in the test fixture can be connected to Signal generator or protocol generator. 

 For USB3.0 Type B plug connector testing. We can soldered DUT on the reference board or terminated in the far end and connected with USB3-BR01A for Impedance and NEXT testing. LiTek Also apply the reference board for standard Type B Plug in option. 

 In some case, we may change the Type B Receptacle for user purpose. Customers can apply their considered type B receptacle to do the USB3-BRXXX as the other test fixtures. 

 

Downloads

[USB3-BR01A] USB3.0 Type B Receptacle Test Fixture Datasheet

add to Twitter add to Plurk add to FaceBook add to Google Plus email to Friends