Language Seletion

Page QR Code

Ramdon Products

 [HDMI2.1-AR01AM] HDMI2.1 type A Rec Fixture
[HDMI2.1-AR01AM] HDMI2.1 type A Rec Fixture
SW4032A Multi-Port Coaxial Switch Box
SW4032A Multi-Port Coaxial Switch Box
[HDMI-CK01A] HDMI1.4 Calibration Kit
[HDMI-CK01A] HDMI1.4 Calibration Kit
[LT-USB3.0-A] USB3.0 Standard Fixture Set
[LT-USB3.0-A] USB3.0 Standard Fixture Set
[HDMI-AP03AR] HDMI Type A Probe Adapter Fixture
[HDMI-AP03AR] HDMI Type A Probe Adapter Fixture
[HDMI-CR02AM] HDMI1.4 Active Type C Receptacle Fixture
[HDMI-CR02AM] HDMI1.4 Active Type C Receptacle Fixture
[USB3-CK01A] USB3.0 2X Trace Calibration Kit
[USB3-CK01A] USB3.0 2X Trace Calibration Kit
[MDP-02ARM] Mini DP Receptacle 15G Fixture
[MDP-02ARM] Mini DP Receptacle 15G Fixture
[MHL-CK01AM] MHL Calibration Kit Fixture
[MHL-CK01AM] MHL Calibration Kit Fixture
[HDMI-DR02AM] HDMI1.4 Active Type D Receptacle Fixture
[HDMI-DR02AM] HDMI1.4 Active Type D Receptacle Fixture

LiTek Calendar

Last MonthMar 2024Next Month
Su Mo Tu We Th Fr Sa
1 2
3 4 5 6 7 8 9
10 11 12 13 14 15 16
17 18 19 20 21 22 23
24 25 26 27 28 29 30
31
Today

Visit Number

Today : 821821821
Total : 2145737214573721457372145737214573721457372145737
Count3770
WebAdmin - MHL | 2011-11-24 15:55:04

Introduction

 The Mobile High-definition Link is an interface for transmitting digital television audiovisual signals from mobile phones, mobile video players, video cameras, still image cameras and other audiovisual source to television sets, projectors, monitors and other video displays.

 LiTek's MHL Calibration fixture (MHL-CK01AM) can be used to calibrate the response of the MHL Type A or MHL Type Micro test fixture .We can get more accuracy by using the Calibration Fixture before testing.

 For MHL Cable Assembly testing, we can reduce the fixture response by calibration. LiTek's MHL Calibration fixture (MHL-CK01AM) is suitable for the LiTek’s MHL test fixture as below :

1. MHL-AR01AM: MHL Type A receptacle test fixture.

2. MHL-MR01AM: MHL Micro B receptacle test fixture. 

3. MHL-MP01AM: MHL Micro Plug test fixture.

 

Downloads

[MHL-CK01AM] MHL Calibration Kit Fixture Datasheet

Count3770
add to Twitter add to Plurk add to FaceBook

The comments are owned by the poster. We aren't responsible for their content.

Copyright © by LiTek All Rights Reserved.
LiTek Technologies Tel:+886-3-4951851 Add:4F-3, No.18, Huannan Rd., Pingzhen City, Taoyuan County, Taiwan 32448
LiTek Precision Tel:+86-755-27331770 Add:901R, Shencai Building, Fuyong Boulevard, Fuyong Town, Bao'an District, Shenzhen, Guangdong, China 51810